Exit Security DoorHardware Solution for Hotel
SOLUTION OVERVIEW
Why an integrated panic hardware system matters — and how AKADA’s internationally certified components protect hotels, offices and public buildings as one complete safety barrier.
CORE HARDWARE COMPONENTS
Five product groups from exterior lever trim to supplementary kit — each with model series, certifications and application notes drawn from the AKADA catalogue.
STANDARD CONFIGURATION & COMPANY
A ready-to-order double-door hardware set with a full bill of quantities, plus an introduction to AKADA’s 30 years of manufacturing strength and service commitment.
Modern building safety depends on a fully integrated emergency hardware system rather than a single component. AKADA designs escape door hardware specifically for fire safety and emergency evacuation — from the exterior lever trim to the door closer — building a complete safety barrier for hotels and commercial buildings.

Certified to Global Standards
Exit devices, hinges and closers are tested by international agencies including CE, EN, UL and ANSI. The system fits wood, metal and stainless steel doors, adapting to different architectural styles and project requirements with confidence.
Full Component Coverage
From keyed exterior lever trim and ball bearing hinges to panic exit devices and door closers, every core part is precision matched. The complete set guarantees rapid response and stable operation at the critical moment of evacuation.
30 Years of Manufacturing
Backed by 30 years of professional manufacturing, AKADA selects zinc alloy and stainless steel with strict process control. A 10-year quality warranty provides long-term, reliable protection for building safety and asset value.
Applicable Buildings of Hardware:
Hotels & Resorts
Star-rated hotels, resorts and serviced apartments. Hardware tuned for quiet operation and elegant finishes — guest safety never comes at the cost of comfort.
Commercial Retail
Shopping malls, supermarkets and premium department stores — durable, good-looking hardware for high-frequency, high-traffic entrances that never stop moving.
Public & Government
Government buildings, corporate offices and mixed-use complexes that demand high security standards together with heavy daily usage and strict compliance.
Public Facilities
Star-rated hotels, resorts and serviced apartments. Hardware tuned for quiet operation and elegant finishes — guest safety never comes at the cost of comfort.
Cultural & Exhibition
Museums, libraries and art centers — balancing the protection of valuable collections and exhibits with safe, code-compliant emergency egress.
Transportation Hubs
Airports, railway stations and passenger terminals, where millions of passages demand hardware that is smooth, reliable and virtually maintenance-free.
Door Design Requirements:
| Door Material | Stainless steel, metal or solid wood leaves — matching modern aesthetics with long-term durability. |
| Opening Style | Flat-opening swing design — smooth, friction-free daily passage with high space efficiency. |
| Structure & Connection | Precision groove-and-tongue leaf construction with high-strength hardware for a solid, durable frame. |
| Leaf Configuration | Standard symmetrical double leaf — balanced and grand, ideal for wide, high-end entrances. |
| Evacuation Direction | Strictly unidirectional outward swing, complying with fire safety codes for rapid emergency egress. |
| Fire Rating | Optional 3-hour fire-rated configuration (UL 10C / EN 1634), or a standard non-rated set for lighter needs. |
Door Hardware Design Requirements:
Exterior Side · Security
The outside of the door is the security line. A keyed lever trim controls entry and zone locking, protecting privacy and assets. The standard set includes a lock cylinder lever handle that supports multi-level key systems — solid, durable and built for high-frequency hotel service.
Interior Side · Egress
The inside of the door is the life passage. A push-bar panic device gives one-motion, barrier-free opening under emergency pressure — fully compliant with fire safety and accessibility codes. Anyone can open the door instantly, with no keys and no twisting motion required.
Access Control · Optional
An optional add-on module, not pre-installed by default. It can be deeply customized and integrated per project — connecting card readers, keypads, fingerprint or facial recognition systems to the electrified exit device series for managed hotel corridors and staff areas.
Material & Finish
The main structure is made of stainless steel 304 or anti-rust zinc alloy, with excellent corrosion and wear resistance. A fine brushed surface presents a restrained metallic texture that blends naturally into modern hotel and commercial interiors.
CORE HARDWARE COMPONENTS
Exterior Lever Trim

The AKADA exterior lever trim is the standard outside trim of the escape door system, engineered for durability and high-frequency daily use. It fits 38–55 mm door thickness and is certified to EN 1634 fire rating. The anti-rust finish resists yellowing, corrosion and wear — keeping a clean architectural look on single- and double-leaf escape doors.
Ball Bearing Hinge

AKADA ULBH hinges are precision machined from stainless steel for heavy-duty, high-frequency escape doors. Ball bearings (2BB / 4BB) minimize friction and wear for smooth, year-after-year operation, while the optional NRP (non-removable pin) version protects the inactive leaf of double doors from lift-off attacks. UL Listed (File No. R41192) with a 3-hour fire rating — one hinge series covers every leaf.
Touch Bar Series

KD-F3000 / 3100 / 3200 with 1- or 2-point locking for standard doors; KD-F3700 narrow-stile touch bar — UL listed, ANSI Grade 1, modular design with up to 4 lock points.One hand, one motion — the door opens instantly under panic pressure, no keys, no twisting. Full stainless steel body, corrosion resistant and built for years of reliable emergency service.
Cross Bar Series

KD-F2100 / 2200 / 2500 — EN 1125 & CE certified; narrow-stile KD-F2516 concealed type; KD-F3600 heavy duty reaching ANSI Grade 1 for high-frequency venues.Standalone alarm (110 dB, battery powered), online alarm, Electric Latch Retraction (ELR) and Motorized Latch Retraction (MLR) modules on the KD-F3600-A series — connecting the escape door to hotel security systems without blocking free egress.
Door Closer

AKADA overhead door closers ensure every escape door closes in a controlled, silent way — protecting the fire seal between compartments and preventing slam damage. Standard models suit 40–65 kg leaves up to 950 mm wide; heavy-duty versions cover larger doors. A precision hydraulic system stays lubricated for long-term, stable performance in high-traffic environments.
Dust-Proof Socket

DS3876 SS / DS3802 SS / YB-038 SN — installed at the threshold, it keeps dust and moisture away from the lower locking point, ensuring reliable latching of the inactive leaf in any environment.
Flush Bolts (Top & Bottom)

YB-034 / YB-063 / YB-037 / YB-069 stainless steel bolts lock the inactive leaf vertically, strengthening sealing and impact resistance on heavy double doors.
