AKADA Door Hardware Solutions


Door opening & closing description:
While fire doors are engineered to withstand fire for designated durations, it is critical to pair them with door hardware that has been fire-tested and certified for the same door assembly to maintain overall fire integrity. This compatible hardware ensures fire doors remain securely closed and properly positioned, thereby containing fire and smoke to inhibit their spread within the building.
and immediate egress during an emergency. This dual functionality is essential to allow occupants to evacuate efficiently without compromising the compartmentalization of fire and smoke.
Therefore, specifying appropriately tested and certified fire door hardware is fundamental to ensuring the intended performance of fire-rated door assemblies and to providing a reliable means of egress for building occupants.
|
School |
High-class club |
Super market |
Air-port building |
|
5-stars hotel |
Museum |
Elderly house |
Shopping mall |
|
Stadium |
Hospital |
High-end office building |
Hotel |
|
Station |
Office Building |
exhibition center |
Government building |
Get Factory-Direct Pricing
SECURING – cylindrical lockset()
Our ANSI Grade 1 Cylindrical Lock has been value-engineered to meet your quality and cost expectations.

LOCKING – Mortise lockset
Our UL mortise locksets are an ideal choice for heavy duty applications in various occupancy types like Commercial buildings, Hotels, Hospitals and Educational Facilities. it will function in excess of 1 Million Cycles, also been certified to the requirements of UL and are suitable for use on fired doors up to 3 hrs.

OPERATING – Handles
Stainless steel fire rated door handles are rigorously tested to EN 1906 and EN 1634 , ensuring they meet building and safety regulations for residential, commercial, and public buildings.

Control | Door Closers
HANGING – Hinges
Our UL10C and ANSI
hinge can suit for differnt door weights: heavy-Duty Hinges: Designed for large and high-traffic
doors found in public buildings, warehouses, or industrial sites. These hinges feature reinforced bearings and thicker
leaf gauges for maximum strength.
Medium-Duty Hinges: Common in offices, schools, and healthcare environments, these are ideal for moderate traffic and
average door weights.
Light-Duty Hinges: Best suited for interior or low-traffic applications, such as small utility or partition doors.”

HANGING – Hinges
Our UL10C and ANSI 3D adjustable invisible hinges provide safety, durability, and modern design for fire doors. Tested for 3-hour fire resistance, these concealed hinges ensure smooth operation and tamper resistance while maintaining a clean, seamless look. Ideal for commercial and residential projects requiring both style and certified fire protection.

HANGING – Hinges
Our UL-listed spring hinge is a self-closing door hinge that integrates a clock spring mechanism into its knuckles to automatically return the door to the closed position.

CONTROLING – Door Closers
Commercial door closers are essential components of many commercial buildings, contributing to safety, security, accessibility, and energy efficiency.Our Door closers are tested under ANSI/BHMA A156.4 Grade 1 to ensure long-term performance.

EXITING – Fire exit devices
Our panic door hardware is ANSI grade 1 (500,000 cycle minimum life) and ADA compliant. Our fire rated panic exit hardware has a UL10C three-hour fire rating.Our panic and fire rated exit devices are fabricated from high-quality steel or stainless steel and are available in either powder coated aluminum or satin stainless steel finishes.

LATCHING – Latches
Similar to locks, latches do not offer the same level of security. They are commonly used on interior doors where security is not a top priority.

SEALING – Smoke Seals
Smoke seals are used to prevent smoke from entering the building through gaps around the door. They must be tested to ensure they can withstand the heat and pressure of fire.

SIGNING – Fire door signs
It is mandatory for all fire doors to have clear signage at eye level on both sides.

Control – Door Coordinators
Door coordinators ensure correct closing sequence for double doors, supporting fire and safety compliance where required.



Operation | Lever Handle
Option A | Tubular / Cylindrical Lever Sets(1500)
Tubular lever sets are based on a bored lock construction with an integrated latch and lever mechanism.
They provide reliable operation with simplified installation and standard door preparation.
Typically specified for residential and light commercial interiors where efficiency and standardisation are required.

Option B | Mortise Lever Sets (M7098-7208006 SS)
Mortise lever sets operate a separate lock body recessed within the door edge, providing increased durability and functional flexibility.
The construction supports higher usage frequency, enhanced security options, and compatibility with fire-rated door assemblies.
Applied in commercial, hospitality, healthcare, and high-traffic interior environments.

Option C | Interconnected Lever Sets(KD-F6200-B)
Interconnected lever sets mechanically link the lever handle and locking mechanism, allowing coordinated operation through a single motion.
This configuration reduces operational error while supporting life-safety and code compliance requirements.
Typically applied to entrance doors in residential and multi-unit housing where controlled access and ease of egress are required.

Hanging | Door Hinges (2–3 pcs)
Option A | Butt Hinges (ULBH 5X4X4.8)
Butt hinges provide direct load-bearing support through a robust, exposed hinge construction.
Manufactured to meet ANSI/BHMA A156.1, Grade 1 performance
requirements for durability and frequent use.
Applied in residential and commercial doors requiring long-term reliability and serviceability.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when evaluated in accordance with UL 10C.

Option B | Concealed Hinges(ZCH016-40)
Concealed hinges provide a flush door appearance with uninterrupted surface continuity.
The hinge mechanism remains hidden when the door is closed, supporting clean architectural
expression and minimal detailing.
Applied in contemporary residential and design-led commercial interiors prioritising visual
clarity.
Fire-Rated Use:
Use on fire-rated door assemblies is permitted only where the hinge type is evaluated and allowed as part of a
UL-listed door assembly.

Option C | Flush Hinges(SS-08)
Flush hinges sit level within the door leaf and frame, reducing visual projection at the door
edge.
This configuration maintains refined detailing while supporting stable door movement.
Applied primarily in interior doors where a restrained appearance is required without full
concealment.
Fire-Rated Use:
Fire-rated use is subject to door and hardware listing limitations and is not generally applicable unless
specifically tested as part of a rated assembly.

Option D | Continuous Hinges(ACGH-01)
Continuous hinges extend the full height of the door, distributing load evenly along the door edge.
This configuration improves durability, alignment stability, and resistance to abuse over time.
Applied in commercial, institutional, and high-traffic environments requiring long service life.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when evaluated in accordance with UL 10C.

Option E | Pivot Hinges(AP600 LH/RH)
Pivot hinges support the door through top and bottom pivot points rather than edge-mounted
leaves.
They allow controlled door movement while accommodating heavier or oversized door leaves.
Applied in commercial entrances, feature doors, and applications requiring enhanced load
control.
Fire-Rated Use:
Fire-rated use is subject to complete door assembly testing and listing and must be confirmed on a
project-specific basis.

Security
Mortise Locks

Option A | Passage & Privacy Mortise Locks(ML70-1)
Passage and privacy mortise locks are designed for interior doors requiring basic access
control or user privacy.
The lock body supports smooth latch operation and clean forend detailing, allowing coordinated
use with contemporary lever handles and concealed hardware.
Applied in residential and light commercial interiors where security requirements are limited
and controlled access is sufficient.
Fire-Rated Use:
Not typically specified for fire-rated door assemblies unless explicitly evaluated as part of a tested assembly.

Option B | Security Mortise Locks
Security mortise locks provide enhanced locking performance through a robust internal lock case
and reinforced latch and bolt mechanisms.
Manufactured to meet
ANSI/BHMA A156.13, Grade 1
performance requirements for durability, strength, and frequent use.
Applied in commercial, hospitality, healthcare, and institutional environments where reliability and security are critical.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when evaluated in accordance with UL 10C as part of a complete door assembly.

Option C | Multi-Function Mortise Locks
Multi-function mortise locks support a wide range of operational functions, including office,
classroom, storeroom, and institutional configurations.
The modular design allows flexible specification while maintaining consistent mechanical
performance across different access requirements.
Applied in commercial and public buildings requiring functional zoning and controlled access
management.
Fire-Rated Use:
Fire-rated use is permitted only where the lock function and configuration are included within a UL
10C-evaluated door assembly.

Option D | Mortise Locks with Access Control Preparation
Mortise locks prepared for access control integration support mechanical cylinders, electronic
trim, or external access control devices.
The lock construction maintains secure latching while allowing compatibility with monitored or
controlled entry systems.
Applied in commercial and institutional projects requiring integration with access control or
building management systems.
Fire-Rated Use:
Suitable for fire-rated door assemblies when the lock configuration and associated hardware are evaluated as
part of a UL 10C-tested assembly.
Door Cylinders

Option A | Standard Cylinders(DB100)
Standard cylinders provide reliable mechanical key operation for daily access control.
Manufactured to meet
ANSI/BHMA A156.5 performance requirements for durability and key operation.
Applied in residential and light commercial environments where basic security and consistent operation are required.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when the cylinder is included within a UL Listed lockset and door assembly.

Option B | High-Security Cylinders(M156)
High-security cylinders are engineered to provide enhanced resistance to common forms of attack, including picking, drilling, and forced manipulation.
The internal mechanism supports increased precision, durability, and long-term key control.
Applied in commercial, institutional, and security-sensitive environments requiring elevated protection levels.
Fire-Rated Use:
Permitted for use on fire-rated door assemblies only where the cylinder is part of a UL Listed locking assembly evaluated for fire performance.

Option C | Master Key / Key Management Cylinders(ICM 6)
Master key cylinders support hierarchical keying systems that allow controlled access across multiple doors and user groups.
They enable centralized key management while maintaining differentiated access levels within a single system.
Applied in commercial, hospitality, healthcare, and institutional buildings requiring structured access control.
Fire-Rated Use:
Fire-rated use is allowed only where the master key cylinder configuration is included within a UL Listed lock and door assembly.

Option D | Cylinders for Access Control Integration(M156T)
Cylinders prepared for access control integration support use with electronic trim, monitoring devices, or controlled entry systems.
They maintain mechanical locking functionality while allowing compatibility with access management solutions.
Applied in commercial and institutional projects requiring coordination between mechanical hardware and access control systems.
Fire-Rated Use:
Suitable for fire-rated door assemblies when the complete lock and access configuration is UL Listed and installed in accordance with listing conditions.
Control | Door Closers
Option Null | No Door Closer (Free-Swing Door)
No door closer is specified where unrestricted door movement and user-controlled operation are preferred.
This configuration allows the door to remain open or closed without automatic control.
Applied in residential rooms, private offices, and low-traffic interior spaces where self-closing is not required by code.
Fire-Rated Use:
Not permitted on fire-rated door assemblies.

Option A | Surface-Mounted Door Closers(KC1055)
Surface-mounted door closers provide controlled closing through an externally mounted hydraulic mechanism.
Manufactured to meet
ANSI/BHMA A156.4 performance requirements, with adjustable closing and latching speeds.
Applied in residential and commercial interiors requiring reliable and easily serviceable door control.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when evaluated in accordance with UL 10C as part of the complete door assembly.

Option B | Concealed Door Closers(KC1006)
Concealed door closers are installed within the door leaf or frame to maintain clean architectural lines.
They provide controlled closing performance while remaining visually discreet within the door construction.
Applied in contemporary commercial and design-led interiors where minimal visual impact is required.
Fire-Rated Use:
Fire-rated use is permitted only where the closer type and installation method are included within a UL 10C-evaluated door assembly.

Option C | Floor Closers (Floor Springs)(AFL-75)
Floor closers provide load-bearing support and controlled closing for heavier doors and high-traffic entrances.
The mechanism is installed below floor level, allowing stable operation and consistent closing performance.
Applied in commercial and public buildings requiring durability, alignment stability, and long service life.
Fire-Rated Use:
Suitable for use on fire-rated door assemblies when evaluated in accordance with UL 10C, subject to door construction and installation conditions.

Option D | Hydraulic Hinges(SS-10A)
Hydraulic hinges integrate load-bearing support and controlled closing within a single hinge mechanism.
They provide smooth self-closing action without the need for a separate surface-mounted door closer.
Applied in commercial interiors, retail environments, and medium-weight doors where visual simplicity and controlled closing are required.
Fire-Rated Use:
Fire-rated use is subject to door assembly testing and listing and must be confirmed on a project-specific basis.
Life Safety | Emergency Exit Devices

Option A | Panic Bars (Crossbar Exit Devices)(KD-F3100-A)
Panic bars are operated by pressure applied across a horizontal actuating bar, allowing immediate and intuitive egress.
Manufactured to meet
ANSI/BHMA A156.3 requirements for panic hardware.
Applied in public buildings, hospitality, retail, assembly spaces, and other high-occupancy environments where rapid evacuation is required.
Fire-Rated / Life Safety Use:
Suitable for use on fire-rated door assemblies when UL Listed and installed in accordance with the conditions of listing.
Option B | Push Pad Exit Devices
Push pad exit devices provide controlled emergency egress through a compact actuating surface.
They offer a reduced visual profile while maintaining reliable life safety performance.
Applied in commercial and semi-public environments where a restrained appearance is preferred without compromising egress requirements.
Fire-Rated / Life Safety Use:
Suitable for use on fire-rated door assemblies when UL Listed and compliant with applicable building codes.

Option C | Exit Devices with Exterior Trim(KD-F6200-B)
Exit devices may be configured with exterior trim, cylinders, or access control interfaces to allow controlled entry from the exterior side.
This configuration maintains free egress from the interior at all times while supporting secure access management.
Applied in commercial, institutional, and controlled-access buildings requiring both security and life safety compliance.
Fire-Rated / Life Safety Use:
Fire-rated use is permitted only where the exit device configuration, trim, and locking components are UL Listed as part of the complete door assembly.

Option D | Vertical Rod Exit Devices(KD-F3160-A)
Vertical rod exit devices engage latching points at the top and bottom of the door leaf, providing secure multi-point latching.
Available in surface-mounted or concealed rod configurations to suit different architectural requirements.
Applied in double doors and wide openings where enhanced door control and alignment are required.
Fire-Rated / Life Safety Use:
Fire-rated applications are permitted only where the specific rod configuration is UL Listed and approved for use on fire door assemblies.
Accessories

Option A | Door Coordinators (Surface-Mounted)(DS004)
Door coordinators control the closing sequence of paired or double doors by ensuring the inactive leaf closes before the active leaf.
This function is essential for maintaining latch engagement and fire separation performance in multi-leaf door assemblies.
Applied in commercial, institutional, and public buildings where double doors are specified.
Fire-Rated Use:
Required on fire-rated double-door assemblies where correct closing sequence is necessary to maintain the integrity of the door assembly, subject to UL Listing of the complete door system.

Option B | Concealed Door Coordinators(DS003)
Concealed door coordinators are installed within the door frame or head, maintaining clean architectural lines.
They provide the same sequencing control as surface-mounted coordinators while remaining visually unobtrusive.
Applied in contemporary commercial interiors and design-led public buildings where visual restraint is required.
Fire-Rated Use:
Permitted on fire-rated door assemblies only where the coordinator type and installation method are included within a UL Listed assembly.

Option C | Automatic Flush Bolts (Fire-Rated)(YB079)
Automatic flush bolts engage or retract in coordination with door movement, allowing the inactive leaf to secure automatically.
When used in fire-rated assemblies, they must allow free egress and automatic retraction upon door operation.
Applied in paired doors where inactive leaf control is required without manual operation.
Fire-Rated Use:
Suitable for fire-rated door assemblies only when UL Listed for fire door applications and installed in accordance with listing conditions.

Option D | Latch Bolts & Auxiliary Latching Hardware(AHP110)
Auxiliary latching hardware supports positive latching in paired or specialty door configurations.
They assist in maintaining door alignment and latch engagement under normal and fire conditions.
Applied where additional latching support is required to meet code or project-specific requirements.
Fire-Rated Use:
Fire-rated use is permitted only where the hardware is included within a UL Listed fire door assembly.
Architectural Hardware Certifications
Products tested to the most stringent international industry standards
more infomation





CNC Turning Process

Classic Plate Door Handle Set

Door Hinge Assortment

Decorative Pull Handle Hardware

CNC Milling Process

Knurled Door Lever on Round Rose

Security Door Mortise Lock Body

Smart Door Lock